6.6. menu
It is a menu related to the CNDO/S program.
The CNDO/S program is bundled with Winmostar. The CNDO/S program is a slight modification of the P083 program registered in the former Japan Chemistry Program Exchange Organization (JCPE, the present Japan Computer Chemistry Society) to correspond to Winmostar. The manual of P083 is here <https://winmostar.com/jp/manual_third_party/cndos_man.pdf>. The CNDO/S program (: file: cndosw.exe) has been compiled with gfortran.
6.6.1. Workflow Setting
Set up and run the CNDO/S calculation flow in project mode.
- Preset
Recalls and saves a preset of settings.
- # of Jobs
Specifies the number of jobs.
- Enable parameter/structure scan
This feature requires the purchase of an add-on. It allows you to run multiple calculations where only certain parameters differ (parameter scan) or to run calculations with the same parameters for multiple structures (structure scan).
Click Config to open the configuration window for the scan calculation. For parameter scans, select %WM_SCAN1% for the Target Variable and enter the parameters you wish to set for %WM_SCAN1% in each row of the Values. Then, enter %WM_SCAN1% in the parameters you want to set in the Workflow Settings window or Keyword Settings window. For structure scan, select %WM_STRUCT% for Target Variable when the animation appears in the molecule display area (e.g., by opening an SDF file).
After the scan calculation is finished, use
to tabulate the calculation results.- Import
Import the settings output by Export. Click the arrow at the right of the button to recall settings used in the past on the same project or Winmostar.
- Export
Output settings to file.
- OK
Runs a calculation or generates a file with your settings. See For project mode for details.
- Details
Set up detailed calculation conditions. The Configure will be launched.
- Task
Specify calculation details. (UV-Vis only)
- Method
Specify calculation method.
- Charge
Specify the charge.
- Multiplicity
Specifies spin multiplicity.
6.6.2. Configure
Set calculation conditions of CNDO/S. To set up the calculations immediately after setting Run button, once to return to the main window please press OK button.
Behavior when clicking Run is see Run.
- Method
Specify the calculation method. (CNDO or INDO)
- Multiplicity
Specify multiplicity.
- Basis set
Specify the basis function. (SP or SPD)
- BONDS
Specifies to output the bond order
- NOINTER
If checked, interatomic distance will not be output.
- SHORT
It outputs a simplified log.
- OUTMO
It outputs a file for MOLMOL 2.
- Repulsion integral
- Specify the expression of repulsion integral.
Parisian
Ohno
Nishimoto - Iga
Theoretical
- Nuclear repulsion energy
- Specify the expression of inter-nuclear repulsion energy.
Za * Zb / 1
Za * Zb * Gamma ab
- PKAPPA
p Specify the value of kappa for electrons.
- DKAPPA
d Specify the value of kappa for electrons.
- Charge
Specify the charge.
- # of CI
Specify the number of states to include in the CI calculation of the excited state. (Max 500)
- # of excited states
Specify the number of excitation states to output the bond order.
6.6.3. Import Keywords
Only keywords (calculation conditions) are read from the existing CNDO/S input file.
6.6.4. Run
If the input file of CNDO/S is open in the main window, execute CNDO/S with that file. If it is not open, save the CNDO/S input file and execute CNDO/S.
Following file will be generated with execution. For example, the file/folder name when the input file is: file: water.cnd is also shown.
type
Description
lst filewater.lst
Calculation log file.
Working Folderwater.cnd_temp\
Working folder.
6.6.5. Open Log File (lst)
Open the lst file with a text editor.
6.6.6. Analyses
6.6.6.1. UV-Vis
Select lst file and display UV-Vis spectrum and molecular orbital.
Refer to UV-Vis Spectrum window, Energy Level Diagram window, Surface Setup / Cubgen window for how to operate the subwindow.