6.5. menu
It is a menu related to MOPAC.
MOPAC6 and MOPAC7 are bundled with Winmostar. If you wish to use other MOPACs, please obtain the MOPAC itself separately and set the path in the Preferences window.
6.5.1. Workflow Setting
Sets up and executes the MOPAC calculation flow in project mode. Local jobs in project mode will use the binary specified in MOPAC(1) in .
- Preset
Loads and saves a preset of settings.
- # of Jobs
Specifies the number of jobs.
- Enable parameter/structure scan
This feature requires the purchase of an add-on. It allows you to run multiple calculations where only certain parameters differ (parameter scan) or to run calculations with the same parameters for multiple structures (structure scan).
Click Config to open the configuration window for the scan calculation. For parameter scans, select %WM_SCAN1% for the Target Variable and enter the parameters you wish to set for %WM_SCAN1% in each row of the Values. Then, enter %WM_SCAN1% in the parameters you want to set in the Workflow Settings window or Keyword Settings window. For structure scan, select %WM_STRUCT% for Target Variable when the animation appears in the molecule display area (e.g., by opening an SDF file).
After the scan calculation is finished, use
to tabulate the calculation results.- Import
Import the settings output by Export. Click the arrow to the right of the button to recall settings used in the past on the same project or Winmostar.
- Export
Output settings to file.
- OK
Run a calculation or generate a file with your settings. See For project mode for details.
- Details
Set up detailed calculation conditions. The Configure will be launched.
- Task
Specifies the type of calculation.
Configuration details Energy Method=1SCF Optimize Method=EF IR Method=FORCE Optimize(TS) Method=TS IRC(Forward) Method=IRC=1LARGE=50 IRC(Reverse) Method=IRC=-1LARGE=50 Scan Method=EFAdd the specified Scan content to the last line of input.- Method
Specify the calculation method (Hamiltonian).
- UHF
Specify whether the calculation should be done in a closed or open shell system.
- Charge
Specify charge.
- Multiplicity
Specifies spin multiplicity.
6.5.2. Configure
Set calculation condition of MOPAC. To set up the calculations immediately after setting Run button, once to return to the main window please press OK button.
Behavior when clicking Run is see (1) Run MOP6W70, (2) Run MOP7W70, (3) Run MOPACX.
return to the default state with Reset button. . Save the current state as the default state with Save as Default button. Restore the default state to the factory condition with .
- Easy Setup
The simple setting window is displayed.
- Hamiltonian
Specify the Hamiltonian to use. The Hamiltonian supported by each version of MOPAC is as follows.
Hamiltonian
Version of MOPAC being implemented
AM1
MOPAC 6, MOPAC 7, MOPAC 93, MOPAC 97, MOPAC 2000, MOPAC 2002, MOPAC 2006, MOPAC 2009, MOPAC 2012, MOPAC2016
PM3
MOPAC 6, MOPAC 7, MOPAC 93, MOPAC 97, MOPAC 2000, MOPAC 2002, MOPAC 2006, MOPAC 2009, MOPAC 2012, MOPAC2016
RM1
MOPAC 2007, MOPAC2016
AM1 EXTERNAL=RM1.rm1
MOPAC 7.1, MOPAC 93, MOPAC 97, MOPAC 2000, MOPAC 2002, MOPAC 2006, MOPAC 2009, MOPAC 2012
PM6
MOPAC 2007, MOPAC 2009, MOPAC 2012, MOPAC2016
PM7
MOPAC 2012, MOPAC2016
MINDO/3
MOPAC 6, MOPAC 7, MOPAC 93, MOPAC 97, MOPAC 2000, MOPAC 2002, MOPAC 2006
MNDO
MOPAC 6, MOPAC 7, MOPAC 93, MOPAC 97, MOPAC 2000, MOPAC 2002, MOPAC 2006, MOPAC 2009, MOPAC 2012, MOPAC2016
MNDO-d
MOPAC 97, MOPAC 2000, MOPAC 2002, MOPAC 2006, MOPAC 2009, MOPAC 2012, MOPAC2016
- Method
Specify the calculation method.
- EF
Perform structure optimization calculation by EF (Eigen Vector Following) method.
- TS
Find the transition state.
- FORCE
Perform vibration analysis.
- 1SCF
Perform SCF calculation only once. (Structure optimization is not performed.)
- IRC
Perform unique reaction coordinate calculation. Energy is not preserved.
- IRC=1
Specify the inverse direction of the 1st reference vibration and calculate the unique reaction coordinate.
- IRC=-1
Specify the positive direction of the first reference vibration and perform the unique reaction coordinate calculation.
- Charge
Specify the value of the charge.
- Multiplicity
Specify multiplicity.
- OPEN
Specify the number of electrons and the number of orbits in open shell calculation.
- MM
- MMOK
Molecular dynamics correction is added to CONH bond.
- NOMM
Molecular mechanics correction is not added to CONH bond.
- GNORM
Specify the threshold value of the energy gradient norm.
- LARGE
Information is output for each specified cycle.
- GRAPH
Create a file to graphically display molecular orbitals. (GPAGH/GRAPHF)
- EXTERNAL
Read parameter file on disk.
- STEP
Specify the step width in reaction coordinate calculation.
- POINT
Specify the number of calculation points in reaction coordinate calculation.
- STEP1/2
Specify the step size in the grid calculation.
- POINT1/2
Specify the number of calculation points in the grid calculation.
- AUX
Create an AUX file for use with another program.
- BONDS
It outputs the final bond order matrix.
- ENPART
Specify the energy split that resolves the energy into 1 center and 2 center terms.
- ESP
Calculate electrostatic potential.
- EXCITED
Optimize the singlet first excited state.
- GEO-OK
Ignore the check if the atom is close to abnormal.
- NOINTER
Interatomic distance is not output.
- OLDFPC
We use the same reference physical quantity value as the old version MOPAC.
- POLAR
Calculate the polarizability.
- PRECISE
Set the convergence judgment condition to 100 times stricter.
- SYMMETRY
Define the structure using symmetry and equivalent conditions.
- UHF
Perform unrestricted Hartree-Fock calculation.
- VECTORS
The final eigenvector (wave function) is output.
- XYZ
Calculation is performed using the XYZ coordinate system.
- Others
Fill in other keywords.
- Coordinate format
Specifies the format of the atomic coordinates (XYZ or Z-matrix).
- Reset
Reset settings.
- Import
Loading configuration file.
- Export
Output configuration file.
6.5.3. Import Keywords
Only keywords (calculation conditions) are read from the existing MOPAC input file.
6.5.4. (1) Run MOP6W70, (2) Run MOP7W70, (3) Run MOPACX
If MOPAC input file is opened in the main window, execute MOPAC using that file. If it is not open, save the input file of MOPAC and execute MOPAC.
When saving the input file, the output format of coordinates changes according to the choice of Coordinate Format ( Z-Matrix or XYZ ) and Coordinate Viewer of Z-Matrix / XYZ tab.
It is assumed that different versions of MOPAC are set for (1) MOP6W70 execution , (2) MOP7W70 execution, and (3) MOPACX execution, and that both are used in different situations. The (1). The difference between :guilabel:`(1) Execute MOP6W70, (2) Execute MOP7W70, and (3) Execute MOPACX is the program path of MOPAC to be launched. The program path used for each menu can be changed in . The default MOP6W70 is MOPAC6 and MOP7W70 is MOPAC7, both of which are built in Winmostar. The (3) Execute MOPACX is intended for use with programs such as MOPAC2012, which you can obtain and specify separately.
Following file will be generated with execution. For example, the file/folder name when the input file is
water.dat
is shown together.
type
Description
out filewater.out
It summarizes the outline of the calculation result.
arc filewater.arc
It is a file summarizing the details of the calculation result.
mgf filewater.mgf
This file is output by specifying the keyword GRAPH and contains information used to draw molecular orbitals. Working Folderwater_mop_temp\
Working folder.
6.5.5. Open Log File (out)
Open out file in a text editor.
6.5.6. Open Log File (arc)
Open arc file with a text editor.
6.5.7. Animation
6.5.7.1. Optimization (arc)
Select the arc file and display the animation of the molecular structure.
For the animation display operation method, see Animation operation area.
6.5.7.2. IRC, STEP (out)
Select out file and display animation of IRC calculation.
For the animation display operation method, see Animation operation area.
6.5.8. Analyses
6.5.8.1. MO & Charges (mgf)
Select the mgf file and display the molecular orbital.
GRAPHF
must be set on keyword. Refer to Energy Level Diagram window, Surface Setup / Cubgen window for how to operate the subwindow.Show charges when you select
.
6.5.8.2. IR (out)
Select the out file and display the IR spectrum.
Vibration calculation must be set with keyword. Refer to IR Spectrum Window for how to operate the subwindow.
6.5.9. Use Job Manager
When checked, use Winmostar Job Manager when executing MOPAC. Otherwise, Winmostar will be in a wait state until calculation by MOPAC is completed, and the output result of MOPAC will be automatically loaded into the main window.
It can also be set from Tools ‣ Preferences menu.